Input Data & Assumptions

The following input data and assumptions were used in this tutorial. You do not have to use these data to follow this tutorial. You can use your own source files and input data. You can also model your own air-side systems and plant information if you wish.

 

Internal Conditions

 

 

Constructions

 

Ground Floor: U-value = 0.22 W per m2.K

 

 

External Wall: U-value = 0.26 W per m2.K

 

 

Internal Wall: U-value = 1.778 W per m2.K

 

 

Roof: U-value = 0.18 W per m2.K

 

 

Panel: Solar Absorptance = 0.9

 

 

Glazing: U-value = 1.744 W per m2.K

 

 

Window Frame: U-value = 2.202 W per m2.K

 

 

Mechanical Services

 

 

Load/%

0

30

100

Efficiency/%

95

95

90

 

 

Building Management Systems

 

 

Shading

 

 

Renewables

 

 

Wind Speed (m/s)

3

4

5

6

7

8

9

Efficiency (%)

20

20

19

16

15

14

14

 

Natural & Mixed Mode Ventilation

 

 

Screenshot of the Windows dialog in the 3D Modeller

 

 

Cross-section to show window height (h), throat size (d), and openable angle (theta)

 

 

Floor Plans (as drawn in Tas)

 

Ground Floor

 

Panels Floor

 